How do you run pipes from a slab to an attic

WebJul 20, 2012 · Need to get a hot water line from one end of the house to the other in a ranch with a concrete slab. Existing ranch has very low ceilings (7-8) so dropping any ceilings will not work. No interior walls to use either. My plan is to run PEX thru the attic BELOW the insulation. Water line would run over the top of the 2x4 bottom truss cord and I would … WebAug 24, 2024 · A rebar-reinforced 4” – 6” thick concrete slab is poured directly on a prepared surface. Plumbing lines are run beneath the slab, where they are difficult to reach. Sometimes the plumbing joints leak or the pipes crack beneath a slab, and then you have one of the most serious problems you could imagine – a slab leak.

Is there a proper way to route PEX through attic?

WebNo, you don't need attic access to do this; it would make it easier for sure, but its not required. You could cut access holes at the top of the wall on the first floor, use a flexible drill bit, drill into the top plate of the first floor and … WebMar 7, 2016 · Option 1 is to cut the concrete and bust out slots to run new pipes. Option 2 is to reroute the pipes some other way. Most commonly it's done up and through the attic. If rerouting the pipes, because of your location, I would use … cryptomaster download https://lafamiliale-dem.com

DIY Radon Mitigation. A Step-by-Step Guide to a Radon-Free Home …

WebJan 11, 2010 · Break the slab, cap them off under the slab and patch up the slab or 2. Break the slab, cap them off and put some sort of access box and cover or 3. Any other/better idea for keeping them from freezing while making them code compliant? Any way to avoid breaking the slab? Gary Swart In the Trades Messages 8,101 Reaction score 82 Points 48 … Webr/Plumbing • 1 mo. ago. Inside of a hot water tank in case you've never seen it. Seven year old apartment complex, tanks have never been flushed. Residents are starting to complain the hot water doesn't last long enough. We tried flushing but it didn't seem to make a difference. We need ideas for a solution, 100 units. WebOct 15, 2024 · A professional discovers which line is leaking under the slab and where the ends come from the slab. They abandon the leaking line and start a new line above the … cryptomates

Can You Run Water Lines in Attic? Should You Insulate?

Category:Slab leak : r/Plumbing - Reddit

Tags:How do you run pipes from a slab to an attic

How do you run pipes from a slab to an attic

Is it OK to run the main water supply line up into attic to …

WebWe have to replace our plumbing which is old galvanized pipe and the house is on a slab. We've had several GCs/architects/plumbers tell us it's best to run the drinking water through the attic (because you could see a leak in the future, the pipes won't get all the toxins from the ground), but we've had one plumber (the cheapest estimate) say that we should do it … WebJul 29, 2024 · If the room below is finished, you'll need to build a soffit around the pipes or run them through the studs. This plan calls for a 3-inch horizontal drain; codes may permit …

How do you run pipes from a slab to an attic

Did you know?

WebStep 4: Place and seal pipe. Run the bottom piece of pipe several inches into the sub-slab pit. Place the backer rod between the outside of the pipe and the slab, then seal the joint using hydraulic cement. Step 5: Run the pipe to a fan. In the attic, the pipe runs to an in-line fan that runs 24/7. You’ll probably need to add an outlet to ... WebHaving analyzed that Attic temperatures should be 10 to 15 degrees warmer with adequate ventilation, it is my opinion that sufficient insulation around PEX tubing should keep the …

WebOct 21, 2024 · When running pipe from a slab to an attic, use cross-linked polyethylene tubing, or PEX, instead of copper. PEX is semi-flexible, which allows for long, continuous runs through joists and... WebJun 3, 2024 · The main concern for gas lines that are run in the attic is lightning strikes. If lightning strikes the gas line directly or near it, then it can create enough heat and energy to make a hole in the line. This can ignite the gas and cause an explosion. Or the gas can simply contribute to a developing fire in the attic.

WebFeb 12, 2024 · There are two types of pipes, other that water supply, that are typically found in an attic: 1) vent pipes for the plumbing drain system, like in the photo above, that extend through the roof and are usually larger diameter and, 2) piping for natural or propane gas that runs through the attic and then down to a furnace …. WebIf you go attic. Insulate both hot and cold water lines good.. Slab. Make sure that the lines can be removed from the slab through a sleeve or something. If not and you have a leak you will not know it until the water has worked its way to an opening. Then it is jackhammer time to find and repair the leak. Just saying.

WebJul 18, 2024 · Building a Wall Chase. A chase is a false wall that creates a cavity used to conceal plumbing. The chase can be stacked from floor-to-floor of the home. This allows plumbing to run from the basement to the attic. The chase is most commonly used for running new vent stacks. Similar to the chase is the soffit.

WebJul 29, 2024 · As a general rule, the drain line for each fixture should connect to a vent within a few feet of the fixture. An actual vent never has water running through it. However, wet venting—routing drain water through a vent—is permitted in some situations. cryptomat loginWebwill call with a 2 hour window. You should plan to be available for full window when scheduling inspection. Rule of thumb – Do not cover anything prior to inspection. ** Failure for any of the above may result in a re-inspection fee of $156.00 ** Inspection Order: 1) Underground - utilities ( optional) 2) Forms & Footing and/or Slab cryptomate stacksWebThis exterior pipe run can be avoided if service entrace is outside of a utility room--or relocated there--since you can then punch straight through the block, and go vertical … cryptomatWebThere are two options: The first is to cut a notch in one or more of the studs. OR USE COUPLINGS. The other method is to cut the pipe into sections short enough to thread … cryptomate review ukWebSteps you can take to prevent pipes in your attic from freezing include: Insulating exposed attic pipes. Installing heat tape. Installing Pex piping. Insulating the space under your roof. Letting your taps drip. Let’s look at all of these steps in … cryptomate incWebRe-plumbs, as they are called, are common in older homes that were originally fitted with galvanized pipes or when a leak develops in the slab. Often, the most economical way to replace the original plumbing is running PVC, CPVC or PEX tubing through existing walls, ceilings and crawl spaces. dusting attachment for dyson stick vaccumWebJun 7, 2024 · Get help with your home improvement projects. Tom can help. Send your questions to Tom: http://homeshowradio.com/ask-tom-tynan/ See more AskTom videos: … cryptomatix